Home › Palm Beach › Boca Raton
ADDISON POINTE AT BOCA RATON, A CONDO
6363 LACOSTA DRIVE, BOCA RATON, FL 33433
SIRS (reserve study) filing status
Not available in this dataset. DBPR publishes SIRS filings only through an interactive database that can’t be downloaded. Look this condo up there (search by name or project number PR72408):
SIRS filed July 2025 or later SIRS filed before July 2025
Overview page: DBPR SIRS Reporting & Database. If it isn’t listed there, that does not prove no study was done. Ask the association board or manager.
Official DBPR condominium record (quoted verbatim)
| Condo Name | ADDISON POINTE AT BOCA RATON, A CONDO |
|---|
| Project Number | PR72408 |
|---|
| File Number | 74448 |
|---|
| County | Palm Beach |
|---|
| Street City State Zip | 6363 LACOSTA DRIVE, BOCA RATON, FL 33433 |
|---|
| Units | 172 |
|---|
| Recorded Date | 01/03/2006 |
|---|
| Primary Status registration, not SIRS | Approved |
|---|
| Secondary Status | Recorded |
|---|
| Managing Entity Number | MA67339 |
|---|
| Managing Entity Name | ADDISON POINTE AT BOCA RATON CONDO ASSN, INC |
|---|
| Managing Entity Address | 6363 LA COSTA DRIVE BOCA RATON FL 33433 |
|---|
Source: DBPR CTMH public records extract condo_PB.csv (download page), file dated 2026-10-15. Verify with DBPR license search. “Primary/Secondary Status” describe the project’s registration with DBPR (e.g. fee filings), not SIRS or building safety.
Milestone inspection — Palm Beach County (unincorporated) records
Matched by condo name; check the building address. Source: Palm Beach County PZB milestone inspection layer.
| BUILDING_NO | Building 1 |
|---|
| BUILDING_ADDRESS | 6284 La Costa Dr Boca Raton FL 33433 |
|---|
| YEAR_BUILT_PER_PAO | 1991 |
|---|
| INSPECTION_STATUS | Review Complete, Pending |
|---|
| P1_STATUS | Accepted - Phase 2 Required |
|---|
| P1_DUE_DATE | 2024-12-31 |
|---|
| P1_ACCEPTANCE_DATE | 2024-02-22 |
|---|
| P2_REQUIRED | Yes |
|---|
| P2_STATUS | Submitted - Repairs Required & Phase 1 Amended Required |
|---|
| P2_DUE_DATE | 2024-08-10 |
|---|
| REPAIRS_REQUIRED | yes |
|---|
| REPAIR_START_DUE_DATE | 2026-07-28 |
|---|
| REPAIR_COMPLETE_DATE | (blank in official record) |
|---|
| MILESTONE_COMPLETION_DATE | (blank in official record) |
|---|
| TEN_YEAR_RECERTIFICATION_YEAR | 2034 |
|---|
| LAST_EDITED_DATE | 2026-10-03 |
|---|
| BUILDING_NO | Building 2 |
|---|
| BUILDING_ADDRESS | 6292 La Costa Dr Boca Raton FL 33433 |
|---|
| YEAR_BUILT_PER_PAO | 1991 |
|---|
| INSPECTION_STATUS | Review Complete, Pending |
|---|
| P1_STATUS | Accepted - Phase 2 Required |
|---|
| P1_DUE_DATE | 2024-12-31 |
|---|
| P1_ACCEPTANCE_DATE | 2024-02-22 |
|---|
| P2_REQUIRED | Yes |
|---|
| P2_STATUS | Submitted - Repairs Required & Phase 1 Amended Required |
|---|
| P2_DUE_DATE | 2024-08-10 |
|---|
| REPAIRS_REQUIRED | yes |
|---|
| REPAIR_START_DUE_DATE | 2026-07-28 |
|---|
| REPAIR_COMPLETE_DATE | (blank in official record) |
|---|
| MILESTONE_COMPLETION_DATE | (blank in official record) |
|---|
| TEN_YEAR_RECERTIFICATION_YEAR | 2034 |
|---|
| LAST_EDITED_DATE | 2026-10-03 |
|---|
| BUILDING_NO | Building 3 |
|---|
| BUILDING_ADDRESS | 6300 La Costa Dr Boca Raton FL 33433 |
|---|
| YEAR_BUILT_PER_PAO | 1991 |
|---|
| INSPECTION_STATUS | Review Complete, Pending |
|---|
| P1_STATUS | Accepted - Phase 2 Required |
|---|
| P1_DUE_DATE | 2024-12-31 |
|---|
| P1_ACCEPTANCE_DATE | 2025-03-04 |
|---|
| P2_REQUIRED | Yes |
|---|
| P2_STATUS | Submitted - Repairs Required & Phase 1 Amended Required |
|---|
| P2_DUE_DATE | 2024-08-10 |
|---|
| REPAIRS_REQUIRED | yes |
|---|
| REPAIR_START_DUE_DATE | 2026-07-28 |
|---|
| REPAIR_COMPLETE_DATE | (blank in official record) |
|---|
| MILESTONE_COMPLETION_DATE | (blank in official record) |
|---|
| TEN_YEAR_RECERTIFICATION_YEAR | 2034 |
|---|
| LAST_EDITED_DATE | 2026-10-03 |
|---|
| BUILDING_NO | Building 5 |
|---|
| BUILDING_ADDRESS | 6283 La Costa Dr Boca Raton FL 33433 |
|---|
| YEAR_BUILT_PER_PAO | 1991 |
|---|
| INSPECTION_STATUS | Review Complete, Pending |
|---|
| P1_STATUS | Accepted - Phase 2 Required |
|---|
| P1_DUE_DATE | 2024-12-31 |
|---|
| P1_ACCEPTANCE_DATE | 2025-03-04 |
|---|
| P2_REQUIRED | Yes |
|---|
| P2_STATUS | Submitted - Repairs Required & Phase 1 Amended Required |
|---|
| P2_DUE_DATE | 2024-08-10 |
|---|
| REPAIRS_REQUIRED | yes |
|---|
| REPAIR_START_DUE_DATE | 2026-07-28 |
|---|
| REPAIR_COMPLETE_DATE | (blank in official record) |
|---|
| MILESTONE_COMPLETION_DATE | (blank in official record) |
|---|
| TEN_YEAR_RECERTIFICATION_YEAR | 2034 |
|---|
| LAST_EDITED_DATE | 2026-10-03 |
|---|
| BUILDING_NO | Building 9 |
|---|
| BUILDING_ADDRESS | 6315 La Costa Dr Boca Raton FL 33433 |
|---|
| YEAR_BUILT_PER_PAO | 1991 |
|---|
| INSPECTION_STATUS | Review Complete, Pending |
|---|
| P1_STATUS | Accepted - Phase 2 Required |
|---|
| P1_DUE_DATE | 2024-12-31 |
|---|
| P1_ACCEPTANCE_DATE | 2024-02-22 |
|---|
| P2_REQUIRED | Yes |
|---|
| P2_STATUS | Submitted - Repairs Required & Phase 1 Amended Required |
|---|
| P2_DUE_DATE | 2024-08-10 |
|---|
| REPAIRS_REQUIRED | (blank in official record) |
|---|
| REPAIR_START_DUE_DATE | (blank in official record) |
|---|
| REPAIR_COMPLETE_DATE | (blank in official record) |
|---|
| MILESTONE_COMPLETION_DATE | (blank in official record) |
|---|
| TEN_YEAR_RECERTIFICATION_YEAR | 2034 |
|---|
| LAST_EDITED_DATE | 2026-10-03 |
|---|
| BUILDING_NO | Building 10 |
|---|
| BUILDING_ADDRESS | 6323 La Costa Dr Boca Raton FL 33433 |
|---|
| YEAR_BUILT_PER_PAO | 1991 |
|---|
| INSPECTION_STATUS | Review Complete, Pending |
|---|
| P1_STATUS | Accepted - Phase 2 Required |
|---|
| P1_DUE_DATE | 2024-12-31 |
|---|
| P1_ACCEPTANCE_DATE | 2025-03-04 |
|---|
| P2_REQUIRED | Yes |
|---|
| P2_STATUS | Submitted - Repairs Required & Phase 1 Amended Required |
|---|
| P2_DUE_DATE | 2024-08-10 |
|---|
| REPAIRS_REQUIRED | (blank in official record) |
|---|
| REPAIR_START_DUE_DATE | (blank in official record) |
|---|
| REPAIR_COMPLETE_DATE | (blank in official record) |
|---|
| MILESTONE_COMPLETION_DATE | (blank in official record) |
|---|
| TEN_YEAR_RECERTIFICATION_YEAR | 2034 |
|---|
| LAST_EDITED_DATE | 2026-10-03 |
|---|
| BUILDING_NO | Building 11 |
|---|
| BUILDING_ADDRESS | 6331 La Costa Dr Boca Raton FL 33433 |
|---|
| YEAR_BUILT_PER_PAO | 1991 |
|---|
| INSPECTION_STATUS | Review Complete, Pending |
|---|
| P1_STATUS | Accepted - Phase 2 Required |
|---|
| P1_DUE_DATE | 2024-12-31 |
|---|
| P1_ACCEPTANCE_DATE | 2024-02-22 |
|---|
| P2_REQUIRED | Yes |
|---|
| P2_STATUS | Submitted - Repairs Required & Phase 1 Amended Required |
|---|
| P2_DUE_DATE | 2024-08-10 |
|---|
| REPAIRS_REQUIRED | (blank in official record) |
|---|
| REPAIR_START_DUE_DATE | (blank in official record) |
|---|
| REPAIR_COMPLETE_DATE | (blank in official record) |
|---|
| MILESTONE_COMPLETION_DATE | (blank in official record) |
|---|
| TEN_YEAR_RECERTIFICATION_YEAR | 2034 |
|---|
| LAST_EDITED_DATE | 2026-10-03 |
|---|
| BUILDING_NO | Building 12 |
|---|
| BUILDING_ADDRESS | 6324 La Costa Dr Boca Raton FL 33433 |
|---|
| YEAR_BUILT_PER_PAO | 1991 |
|---|
| INSPECTION_STATUS | Review Complete, Pending |
|---|
| P1_STATUS | Accepted - Phase 2 Required |
|---|
| P1_DUE_DATE | 2024-12-31 |
|---|
| P1_ACCEPTANCE_DATE | 2025-03-04 |
|---|
| P2_REQUIRED | Yes |
|---|
| P2_STATUS | Submitted - Repairs Required & Phase 1 Amended Required |
|---|
| P2_DUE_DATE | 2024-08-10 |
|---|
| REPAIRS_REQUIRED | (blank in official record) |
|---|
| REPAIR_START_DUE_DATE | (blank in official record) |
|---|
| REPAIR_COMPLETE_DATE | (blank in official record) |
|---|
| MILESTONE_COMPLETION_DATE | (blank in official record) |
|---|
| TEN_YEAR_RECERTIFICATION_YEAR | 2034 |
|---|
| LAST_EDITED_DATE | 2026-10-03 |
|---|
| BUILDING_NO | Building 13 |
|---|
| BUILDING_ADDRESS | 6332 La Costa Dr Boca Raton FL 33433 |
|---|
| YEAR_BUILT_PER_PAO | 1991 |
|---|
| INSPECTION_STATUS | Review Complete, Pending |
|---|
| P1_STATUS | Accepted - Phase 2 Required |
|---|
| P1_DUE_DATE | 2024-12-31 |
|---|
| P1_ACCEPTANCE_DATE | 2025-03-04 |
|---|
| P2_REQUIRED | Yes |
|---|
| P2_STATUS | Submitted - Repairs Required & Phase 1 Amended Required |
|---|
| P2_DUE_DATE | 2024-08-10 |
|---|
| REPAIRS_REQUIRED | (blank in official record) |
|---|
| REPAIR_START_DUE_DATE | (blank in official record) |
|---|
| REPAIR_COMPLETE_DATE | (blank in official record) |
|---|
| MILESTONE_COMPLETION_DATE | (blank in official record) |
|---|
| TEN_YEAR_RECERTIFICATION_YEAR | 2034 |
|---|
| LAST_EDITED_DATE | 2026-10-03 |
|---|
| BUILDING_NO | Building 15 |
|---|
| BUILDING_ADDRESS | 6339 La Costa Dr Boca Raton FL 33433 |
|---|
| YEAR_BUILT_PER_PAO | 1991 |
|---|
| INSPECTION_STATUS | Review Complete, Pending |
|---|
| P1_STATUS | Accepted - Phase 2 Required |
|---|
| P1_DUE_DATE | 2024-12-31 |
|---|
| P1_ACCEPTANCE_DATE | 2025-03-04 |
|---|
| P2_REQUIRED | Yes |
|---|
| P2_STATUS | Submitted - Repairs Required & Phase 1 Amended Required |
|---|
| P2_DUE_DATE | 2024-08-10 |
|---|
| REPAIRS_REQUIRED | (blank in official record) |
|---|
| REPAIR_START_DUE_DATE | (blank in official record) |
|---|
| REPAIR_COMPLETE_DATE | (blank in official record) |
|---|
| MILESTONE_COMPLETION_DATE | (blank in official record) |
|---|
| TEN_YEAR_RECERTIFICATION_YEAR | 2034 |
|---|
| LAST_EDITED_DATE | 2026-10-03 |
|---|
| BUILDING_NO | Building 16 |
|---|
| BUILDING_ADDRESS | 6347 La Costa Dr Boca Raton FL 33433 |
|---|
| YEAR_BUILT_PER_PAO | 1990 |
|---|
| INSPECTION_STATUS | Review Complete, Pending |
|---|
| P1_STATUS | Accepted - Phase 2 Required |
|---|
| P1_DUE_DATE | 2024-12-31 |
|---|
| P1_ACCEPTANCE_DATE | 2025-03-04 |
|---|
| P2_REQUIRED | Yes |
|---|
| P2_STATUS | Submitted - Repairs Required & Phase 1 Amended Required |
|---|
| P2_DUE_DATE | 2024-08-10 |
|---|
| REPAIRS_REQUIRED | (blank in official record) |
|---|
| REPAIR_START_DUE_DATE | (blank in official record) |
|---|
| REPAIR_COMPLETE_DATE | (blank in official record) |
|---|
| MILESTONE_COMPLETION_DATE | (blank in official record) |
|---|
| TEN_YEAR_RECERTIFICATION_YEAR | 2034 |
|---|
| LAST_EDITED_DATE | 2026-10-03 |
|---|
| BUILDING_NO | Building 17 |
|---|
| BUILDING_ADDRESS | 6355 La Costa Dr Boca Raton FL 33433 |
|---|
| YEAR_BUILT_PER_PAO | 1990 |
|---|
| INSPECTION_STATUS | Cycle Complete |
|---|
| P1_STATUS | Accepted - Phase 2 Not Required |
|---|
| P1_DUE_DATE | 2024-12-31 |
|---|
| P1_ACCEPTANCE_DATE | 2025-03-04 |
|---|
| P2_REQUIRED | Yes |
|---|
| P2_STATUS | Submitted - Repairs Required & Phase 1 Amended Required |
|---|
| P2_DUE_DATE | (blank in official record) |
|---|
| REPAIRS_REQUIRED | (blank in official record) |
|---|
| REPAIR_START_DUE_DATE | (blank in official record) |
|---|
| REPAIR_COMPLETE_DATE | (blank in official record) |
|---|
| MILESTONE_COMPLETION_DATE | 2025-03-04 |
|---|
| TEN_YEAR_RECERTIFICATION_YEAR | 2034 |
|---|
| LAST_EDITED_DATE | 2026-10-03 |
|---|
Watch ADDISON POINTE AT BOCA RATON, A CONDO for changes — $9/mo
We’ll email you when the official record changes. (Coming soon.)
Start alerts (coming soon)